What was found
APU FAULT AFTER 3 ATTEMPTS. PERFORMED APU OPS CHECK OF THE APU IAW AMM 49-11-00. APU BITE PROCEDURES IAW FIM 4-11 FT 958 FOUND A/C START CIRCUIT MGS ON ECU /LRU SUMMARY RESET. MEMORY RAN APU COULD NOT DUPLICATED, A/C OK FOR SERVICES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT AFTER 3 ATTEMPTS. PERFORMED APU OPS CHECK OF THE APU IAW AMM 49-11-00. APU BITE PROCEDURES IAW FIM 4-11 FT 958 FOUND A/C START CIRCUIT MGS ON ECU /LRU SUMMARY RESET. MEMORY RAN APU COULD NOT DUPLICATED, A/C OK FOR SERVICES.