What was found
FWD FLOORBEAM CORROSION. REPAIR AREA NEW UPPER CHORD IS FROM STA 1540, LBL 62 OVERLAP CORROSION AREA. REPAIR IAW SRM 53-00-51-2R-3 REV 83 AND EI 72018A53M-4121 REV 1 AND DWG 65B38077 SH7 REV. COND CHK NML AND JOB COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD FLOORBEAM CORROSION. REPAIR AREA NEW UPPER CHORD IS FROM STA 1540, LBL 62 OVERLAP CORROSION AREA. REPAIR IAW SRM 53-00-51-2R-3 REV 83 AND EI 72018A53M-4121 REV 1 AND DWG 65B38077 SH7 REV. COND CHK NML AND JOB COMPLETED.