What was found
MID CABIN TEMP BEFORE ENGINE START. REMOVED AND REPLACED MID ZONE TRIM AIR MODULATION VALVE IAW AMM 21-61-07. OPS CK OK. REMOVED AND REPLACED AUX ZONE TEMP CONTROL IAW AMM 21-51-12. TEMP CONTROLLER S/N OFF 029C-116 P/N OFF 115C406-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID CABIN TEMP BEFORE ENGINE START. REMOVED AND REPLACED MID ZONE TRIM AIR MODULATION VALVE IAW AMM 21-61-07. OPS CK OK. REMOVED AND REPLACED AUX ZONE TEMP CONTROL IAW AMM 21-51-12. TEMP CONTROLLER S/N OFF 029C-116 P/N OFF 115C406-1.