What was found
DURING ENGINE RUNS WITH PACKS OPERATING, THE LEFT PACK OUT TEMP READS -12. TROUBLESHOT IAW FIM 21-61-FT, AND FIM 21-61-FT803. FOUND THE FLIGHT DECK ZONE TEMP SENSOR WITH A FAULT INDICATION. PERFORMED A BITE TEST & RESET THE CONTROLLER IAW AMM 21-51-14-705-035. PERFORMED A COOLING PACK TEST IAW AMM 21-51-03-404-016. OPS CHECKED GOOD.