What was found
FWD EQPT VALVE EICAS MSG AFTER BOTH ENGINE STARTED C/W QRH AND VALVE LIGHT REMAINED ILLUMINATED (<P>RE-OPENED MDDR # 108533 IAW DDG 21-58-06 CAT D DUE DATE 09-JUL-19</P><P>LP 880616- ACCOMPLISHED FIM TASK 21-58-00 FIG 104A - NO FAULTS NOTED. ACCOMPLISHED EQPT COOLING SYSTEM VALVE HEALTH CHECK PER AMM 21-58-00-700-805. VALVES CHECKS OK. MDDR CONTINUES (WAITING TD RELAY PN TDH1852-3002</P><P>LP 880617 - REMOVED AND REPLACED 30 SEC TIME DELAY RELAY K1206 PER WDM 21-58-11 OPS CHECKS OK PER AMM 21-58-00. MDDR 108533 CLEARED PLACARD REMOVED </P>)