As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R CENTER TANK PUMP EICAS(<P>TRANSFER TO MDDR 108944 IAW MEL 28-22-02A CAT C DUE DATE 29-MAR-19</P><P>FOUND 3 WIRES BEHIND P61 TO BE ARCHING, REF LP 1065470 ITEM 3 FOR SIGN OFF. PERFORMED OPS CHECK OF CENTER TANK FUEL PUMP IAW AMM 28-00-00. OPS CHECK NORMAL AT THIS TIME. CLEARED MDDR 108944 AND PLACARD REMOVED. <BR /></P>)