What was found
RT ENGINE HPSOV EICAS AND RT ENG HPSOV STATUS MSG(<P>TRANSFERRED TO DMI #110310 IAW MEL 36-11-02-02 CAT C. MCC NOTIFIED, PLACARD INSTALLED. SEE LOG PAGE 1050138 ITEM 6 FOR T/R DEACTIVATION.</P><P>LP 1050141 - M2: T/S IAW 767 FIM 36-20 FAULT TREE 804 AND BITE MODULE FAULTED HPSOV CONTROLLER. NO TIME TO CHANGE PART. DMI 110310 REMAINS OPEN.</P><P>LP 1050143 - M2: REMOVED AND REPLACED HIGH PRESSURE CONTROLLER IAW AMM 36-11-08. PERFORMED BITE OF THE AIR SUPPLY MODULE AND OPS CHECK OF SYSTEM IAW AMM 36-11-07. OPS CHECK GOOD AT THIS TIME. THIS CLEARS MDDR 110310 AND PLACARD REMOVED. </P>)