What was found
FX-CENTER FUEL TANK LWR SURFACE AT STA 1067 RBL 12 FOUND CORROSION(<P>CORROSION REMOVED I.A.W SRM 51-10-02 AND DAMAGE WITHIN ALLOWABLE LIMIT IN SRM 57-10-01 FIG.101<BR /></P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.