As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHEN L FUEL CONTROL SWITCH TO CUT OFF, LT ENGINE REMAINED RUNNING FOR 15/20 SEC, THEN L ENGINE VALVE ANNUNCIATOR LIGHT ILLUMINATED. (<P>REMOVED FUEL SHUTOFF SOLENOID IAW AMM 73-21-20-004-001-H00. INSTALLED SERVICEABLE SOLENOID VALVE - HMU IAW AMM 73-21-20-404-007-H00. OPS AND LEAK CHECKS GOOD. </P>)