What was found
FOUND LT WING OTBD AILERON DELAMINATION. (<P>CUT OUT THE DELAMINATION MATERIAL AND CLEANED. MEASURED THE DAMAGED AREA (L = 2", W = 0.7", D = 4 PLIES 0), (FROM AFT EDGE .69 FROM INBD EDGE, WBL 918), BOND PLIES (L = 8", W = 5"). USED WET LAYUP WITH RESIN, CURED AT 200 DEG F FOR 240 MINUTES AND MAINTAINED MINIMUM VACUUM PRESSURE AT 32 IN/HG IAW SRM 57-60-01-2R-2. REFER TO SRM 51-70-04-2R-0 REV. 27. MADE AN ENTRY OF REWORK MOMENT ON THE ALUMINUM FOIL MOMENT MARKER. IAW SRM 51-60-01-0G-0 REV. 27, CHECK CONDITION WAS SATISFACTORY.</P>)