What was found
APU DOES'T START. (<P>TRANSFER TO MDDR #114547 IAW MEL 49-11-01A CAT "C" DUE DATE 21-JUL-19 PLACARD INSTALLED. </P><P>LP 1050740 - M5: TS APU IAW FIM TASK 49-11 FAULT TREE 989, FOUND BOLT ON INLET GUIDE VANE ACTUATOR COVER IMPROPERLY INSTALLED. NEEDS BOLT, PN M512180-37, MDDR 114547 REMAINS OPEN.</P><P>LP 1050742 - M3: UPON FURTHER T/S, FOUND FLOW SENSING MODULE PACK GASKET RUPTURED. PLACED P/N 3876415-4 ON ORDER WITH MCC, DMI 114547 REMAINS OPEN. </P><P>LP 1050744 - M4: REPLACED TOTAL PRESSURE FLOW SENSOR GASKET IAW AMM 49-53-03. APU STARTS GOOD. MDDR REMAINS OPEN FOR BOLT, ON IGV COVER</P><P>LP 1050745 - M7: INSTALLED IGV COVER BOLT IAW AMM 49-52-03 STEP D. THIS CLEARS MDDR 114547. </P><P><BR /></P><P>NOTE - OPENED MDDR 114798 - FOR APU COLD SOAK START VERIFICATION (25-AP-01) </P>)