What was found
ON EXITING RW, TWR ADVISED SMOKE & FIRE EMANATING FROM LEFT MAIN GEAR. EMERGENCY VEHICLES RESPONDED & SPRAYED GEAR.(<P>REMOVED AND REPLACED #6 BRAKE ASSY IAW AMM 32-41-08, OPS CHECK GOOD. PERFORMED ANTI-SKID OPERATIONAL TEST AND BITE TEST IAW AMM 32-42-00, NO FURTHER DEFECTS NOTED AT THIS TIME . INSPECTED AXLE, NO DEFECTS NOTED. </P><P>LP 1058502 - M4: AS PRECAUTION, REMOVED AND REPLACED #5 MWA IAW AMM 32-45-01. VERIFIED AXLE WASHER INSTALLATION OK. </P><P>LP 1058502 - M6: PERFORMED HIGH ENERGY STOP INSPECTION IAW AMM 05-51-14. NO DEFECTS NOTED AT THIS TIME.</P>)