What was found
EICAS RIGHT PACK TEMP, RIGHT PACK OFF. ACCOMPLISHED QRH PROCEDURES. (<P>PERFORMED PACK CONTROL SYSTEM BITE TEST IAW FIM 21-51-00, NO FAULTS NOTED, PACK OPS CHECK NORMAL.</P><P>LP 823381 - M5: RIGHT PACK FAILED ON GROUND. TRANSFERRED TO MDDR 115034 AS PER DDG 21-51-03, CAT "C". PACK TEMP CONTROL AUTO MODE INOP. </P><P>LP 823385 - M9: PREFORMED PACK TEMP CONTROLLER BITE TEST, FOUND LOW LIMIT VALVE FAULTY. REMOVED AND REPLACED LOW LIMIT VALVE, OPS AND LEAK CHECK GOOD. ALL WORK DONE PER AMM 21-51-14 AND 21-51-11. THIS CLEARS DMI 115034.</P><P><BR DATA-MCE-BOGUS="1" /></P><P>NOTE: ACCOMPLISHED DURING A-CHECK (MIA), REF NRC 00011.</P>)