As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT SPAR VALVE DID NOT ILLUMINATE. TEST LIGHT OK BEFORE SHUT DOWN. PERFORMED FUNCTIONAL CHECK OF BOTH LEFT AND RIGHT SPAR VALVES IAW AMM 28-22-00, FUNCTIONAL TEST NORMAL. ALSO, PERFORMED RT ENGINE IDLE RUN AND OPS CHECK OF SPAR VALVE IS NORMAL.</P>)