CABIN STA 820 - 940, RBL 40, FLOOR SUPPORT TRACK FOUND CORROSION. CORROSION REMOVED AS PER SRM 51-10-02. BLEND OUT DEPTH 0.035", ORG 0.090", WIDTH 1", LENGTH 6" OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT. CABIN STA 820 - 940, RBL 40, FLOOR SUPPORT TRACK REPAIRED IAW SRM 53-00-52-2R-5 REPAIR 5 AND EO 4453B734.