What was found
FWD OUTFLOW VALVE CANT FULLY CLOSE DURING PFM CABIN PRESSURING TEST(<P>REPLACE THE OUTFLOW VLV ACTUATOR. PERFORM CABIN PRESS TEST AND RESULT PASS IAW <SPAN>AMM 21-31-04-004-001 </SPAN><SPAN>AMM 21-31-04-404-010</SPAN></P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD OUTFLOW VALVE CANT FULLY CLOSE DURING PFM CABIN PRESSURING TEST(<P>REPLACE THE OUTFLOW VLV ACTUATOR. PERFORM CABIN PRESS TEST AND RESULT PASS IAW <SPAN>AMM 21-31-04-004-001 </SPAN><SPAN>AMM 21-31-04-404-010</SPAN></P>)