What was found
DURING APPROACH, LEFT PACK TEMP EICAS MESSAGE. PACK OPERATED IN STANDBY MODE AFTER PACK RESET. TRANSFERRED TO MDDR 117124 PER MEL 21-51-03-01, CAT C, DUE 10-SEP-19. PLACARDS INSTALLED AND MCC NOTIFIED. LP 1073215 - M3: T/S PACK CONTROL SYSTEM AND FOUND TRIM AIR SUPPLY VALVE INSTALLED BACKWARDS. REMOVED AND RE-INSTALLED TRIM AIR SUPPLY VALVE IAW AMM 21-61-05. OPS CHECKS GOOD, NO FAULTS AT THIS TIME. THIS CLEARS MDDR 117124. MCC NOTIFIED AND PLACARDS REMOVED.