M/D - FLOOR SUPPORT FOUND CRACKED STA 500 TO 520, RBL 65, CABIN STA 500 - 520, RBL 65, FLOOR SUPPORT FABRICATED PER DWG 69B19165-1, AND PL, AND FASTENER INSTALLED AS PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
M/D - FLOOR SUPPORT FOUND CRACKED STA 500 TO 520, RBL 65, CABIN STA 500 - 520, RBL 65, FLOOR SUPPORT FABRICATED PER DWG 69B19165-1, AND PL, AND FASTENER INSTALLED AS PER SRM 51-40-02.