What was found
M/D STA 1180 - 1220, RBL 77, SEAT TRACK O/B FLANGE FOUND CORROSION.(<P>M/D STA 1180 - 1200, RBL 77, SEAT TRACK O/B FLANGE CORROSION REMOVED AND RE-PROTECTED AS PER SRM 51-10-02 AND SRM 51-20-01. BLEND OUT DEPTH 0.005", ORG 0.071", WIDTH 0.7", LENGTH 4" WITHIN SRM 53-00-52 ALLOWABLE DAMAGE FIG 101 LIMIT.<BR /></P>)