What was found
CTR R FUEL PUMP EICAS MESSAGE AFTER ENGINE START WITH CENTER TANK FUEL. REMOVED AND REPLACED K10692, RT RELAY IAW SWPM 20-81-11. OPS CHECK OK PER AMM 28-22-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CTR R FUEL PUMP EICAS MESSAGE AFTER ENGINE START WITH CENTER TANK FUEL. REMOVED AND REPLACED K10692, RT RELAY IAW SWPM 20-81-11. OPS CHECK OK PER AMM 28-22-00.