Service difficulty report · Wire · Boeing 74747UF

Difficulty date
October 8, 2019
Submitted
October 16, 2019
Operation
Air carrier
Aircraft
N493MC
Make and model
Boeing 74747UF
Aircraft serial
29254
Aircraft time
86,333 hours, 13,894 cycles
Part
Wire
Condition
Broken
Location
Outflow Valve
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

OUTFLOW VALVE RIGHT EICAS MSG ON TAKE OFF ROLL STATUS MSG. UNABLE TO CLOSE OUTFLOW VALVE IN MANUAL OR AUTO. FOUND A BROKEN WIRE AFT SIDE CEILING. REMOVED AND REPLACED CABIN PRESSURE CONTROLLER B. OPS CHECK GOOD AT THIS TIME IAW AMM 21-31-02. REMOVED AND REPLACED L/H ICU DUE TO WIRES SHORTING UNIT OUT. OPS CHECK GOOD AT THIS TIME IAW B747 AMM 21-31-10. REMOVED AND REPLACED R/H ICU DUE TO WIRES SHORTING UNIT OUT. OPS CHECK GOOD AT THIS TIME IAW B747 AMM 21-31-10. REPAIRED WIRING IAW SPW 20-30-123.