What was found
CLIMBING THRU ~ 10,000 FT, OBSERVED R ENG ANTI-ICE ON EICAS. R ENGINE ANTI-ICE SW "VALVE" DISAGREEMENT LIGHT. (<P>PERFORMED RIGHT ENGINE ANTI-ICE THERMAL VALVE OPERATIONAL TEST IAW AMM 30-21-00, OPS CHECK NORMAL. CYCLED ANTI-ICE VALVE LIGHT, EXTINGUISHED AS COMMANDED. NO DEFECTS NOTED AT THIS TIME. </P>)