What was found
ON CLIMB OUT, LEFT BLEED LIGHT ILLUMINATED. NO EICAS MSG. LIGHT STAYED ON FOR SEVERAL MINUTES, NO EICAS MSG, THEN IT WENT OUT. WRITTEN UP BEFORE. PERFORMED AIR SUPPLY BITE TEST, NO FAULTS, REF AMM 36-20 FT 805 AND 36-23-00. REMOVED AND RE-RACKED AIR SUPPLY CONTROLLER, REF AMM 36-11-02. PERFORMED AIR SUPPLY PRESSURE IND. CHECKS, REF AMM 36-21-00. OPS CHECKS GOOD. ACFT RELEASED FOR FLIGHT.