Service difficulty report · Warning System · Boeing 767375

Difficulty date
January 14, 2020
Submitted
January 15, 2020
Operation
Air carrier
Aircraft
N1709A
Make and model
Boeing 767375
Aircraft serial
24086
Aircraft time
93,566 hours, 21,893 cycles
Part
Warning System
Condition
False Activation
Location
Cockpit
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB OUT, LEFT BLEED LIGHT ILLUMINATED. NO EICAS MSG. LIGHT STAYED ON FOR SEVERAL MINUTES, NO EICAS MSG, THEN IT WENT OUT. WRITTEN UP BEFORE. PERFORMED AIR SUPPLY BITE TEST, NO FAULTS, REF AMM 36-20 FT 805 AND 36-23-00. REMOVED AND RE-RACKED AIR SUPPLY CONTROLLER, REF AMM 36-11-02. PERFORMED AIR SUPPLY PRESSURE IND. CHECKS, REF AMM 36-21-00. OPS CHECKS GOOD. ACFT RELEASED FOR FLIGHT.