What was found
3RD TIME WRITE UP, "R ENG PRV" EICAS. ACCOMPLISHED QRH. R ENG PRV STATUS REMAIN.(<P>ON #2 ENG, SWAPPED PRV AND HPSOV PER MX CONT REQUEST IAW B767 AMM 36-11-18 AND 36-11-07. PERFORMED ENGINE RUN, OPS CHECK NORMAL.</P><P>LP 1086917 - ITEM M3: <SPAN>PER MAINTENANCE CONTROL REQUEST, </SPAN><SPAN>INSTALLED BLEED AIR CONTROL CARD FOR R ENG M860. FOUND TO BE BFS. REINSTALLED PREVIOUSLY REMOVED CARD. OPS CHECK NORMAL IAW B767 AMM 36-11-12. PART EFFECTIVITY VERIFIED.</SPAN></P><P>LP 1086918 - ITEM M5: <SPAN>WHILE REMOVING HPSOV FOUND E-SEAL MISSING ON #2 ENG. </SPAN><SPAN>INSTALLED NEW E-SEAL FOR HPSOV ON #2 ENG IAW B767 AMM 36-11-07. PART EFFECTIVITY VERIFIED. OPS CHECK NORMAL.</SPAN></P><P>LP 1086918 - ITEM M6: PERFORMED FIM 36-10 FAULT TREE 847. MESSAGE CLEARED.</P>)