What was found
L ENG OH LP 1 STATUS MSG.(<P>TRANSFERRED TO MDDR #125372 I.A.W MEL 26-11-02-01, CAT C.</P><P>LP 1208441: PERFORMED FIM TASK 26-11 FAULT TREE 804 FOR ENGINE FIRE DETECTION SYSTEM BITE PROCEDURES, COULD NOT DUPLICATE THE L ENG ON LP 1 STATUS MSG. OPS CHECKS NORMAL AT THIS TIME. C/W WO # 63683 WITH ACCOMPLISHMENT OF TROUBLESHOOTING. DMI REMAINS OPEN FOR FURTHER TROUBLESHOOTING.</P><P>LP 1208451: PERF. DVI AND CLEANING OF ALL FIRE DET. ELEMENTS. NO DEFECTS NOTED. PER AMM 26-11-02/701. RERACKED ENG #1 LOOP 1 AFOLTS CARDS PER AMM 26-11-02. PERF ENG. FIRE 1 OVERHEAT TEST IAW AMM 26-11-01. TEST OK. PERF ENGINE RUN IAW AMM 71-00-00, COULD NOT DUPLICATE. NO MSG NOTED.</P><P>LP 1208456: OBSERVED NO EICAS MSG PER MCC, THIS CLEARS DMI 125372, PLACARD REMOVED.</P><P><BR /></P>)