What was found
PRIOR TO ENGINE START, WITH SELECTION OF HYDRAULIC DEMAND PUMPS, APU AUTO SHUT DOWN DUE TO RIGHT EEC CB CHANNEL A.(<P>RESET CB, REF FIM 73-21 FT 885, NO FAULTS NOTED.</P><P>ITEM 2: APU STARTED FIRST ATTEMPT, NO APU WORK DONE, NO FAULTS NOTED. NO COLD SOAK REQUIRE. REF AMM 49-11-01.<BR DATA-MCE-BOGUS="1" /></P>)