LEFT ISOLATION VALVE DOESN'T OPEN WITHOUT REPETITIVE RE-CYCLING OF BUTTON. PERFORMED LEFT ISOLATION VALVE TEST IAW AMM 36-11-04-214-022 AND FOUND GOOD.