What was found
STATUS MSG L ENG FIRE LOOP 1(<P>ISSUED MDDR 133103 IAW MEL 26-11-01-01, CAT C, DUE 29AUG20.</P><P>LP 1297199: PERFORMED VISUAL INSPECTION ON LOWER FWD ENG #1 FIRE DETECTOR. FOUND DETECTOR ELEMENT TOUCHING THE SUPPORT TUBE IAW FIM 26-11 FT 802. READJUSTED ELEMENT AWAY FROM SUPPORT TUBE. PERFORMED FIM 26-11 FT 805. OPS CHECKS NORMAL. NO FAULTS OR STATUS MESSAGE NOTED. THIS CLEARS MDDR 133103. MCC NOTIFIED.</P><P>LP 1297200: TRANSFERRED (RE-OPENED) TO DMI 133103 PER MEL 26-11-01-01 CAT "C". DDPG PROCEDURES C/W.</P><P>LP 1274715, ITEM M11: REMOVED AND REPLACED FIRE CARD M681. OPS CK GOOD IAW 767MM 20-41-01 & 26-11-00. PERFORMED WIRING CHECK OF DETECTORS, NO DEFECTS NOTED IAW 767 WDM 26-11-01. THIS ITEM CLEARS DMI # 133103. PLACARDS REMOVED. MCC JESUS NOTIFIED. T/I: TJ @ 15:19Z.</P>)