What was found
CORROSION ON FLOOR BEAM UPPER CAP AT STA 2240 BETWEEN LBL 50.00 AND LBL 67.01. ACCOMPLISHED JOB IAW EI NO T2020A53M-1983 REV 1 AND SRM 53-00-51-2R-2, REPAIR 3, REV 89. JOB COMPLETED AND CONDITION CHK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR BEAM UPPER CAP AT STA 2240 BETWEEN LBL 50.00 AND LBL 67.01. ACCOMPLISHED JOB IAW EI NO T2020A53M-1983 REV 1 AND SRM 53-00-51-2R-2, REPAIR 3, REV 89. JOB COMPLETED AND CONDITION CHK NORMAL.