LEFT AND RIGHT DME INOPERABLE P/N DM 1601354-001. REMOVED AND REPLACED DME RT INTERROGATOR M124, OPS CHECK OK AMM 34-55-01. REMOVED AND REPLACED DME LT ANTENNA M263, OPS CHECK OK AMM 34-55-02. MDDR 133403 CLEARED UP, PLACARD REMOVED. P/N OFF 622-4540-122, S/N 6506, S/N ON 5818.