What was found
CENTER RT FUEL PUMP EICAS MESSAGE CENTER TANK FUEL PUMPS, ONE INOPERATIVE, CENTER TANK FUEL USED. NOTIFY DISPATCH. TRANSFERRED TO MDDR 136097, IAW MEL 28-22-02A, CAT C 10/17/2020. REVERSED DDG, PERFORM FIM 28-22 TASK 805, NO FAULTS NOTED AND SYSTEM TESTED GOOD, IAW AMM 28-22-00. THIS CLEARS MDDR 136097, PLACARD REMOVED, MCC NOTIFIED. (TI: LC 1552Z)