"FIRE/OVERHEAT SYSTEM" EICAS MESSAGE. ACCOMPLISHED QRH AND MESSAGE CLEARS BUT COMES BACK WITHIN 2-3 MINS. REMOVED/REPLACED AFOLT CARD M10224 ENGINE RT; PERFORMED FIRE/OVERHEAT ENGINE SYSTEM TEST OK, AMM 26-10-01.