What was found
NR 1 ENGINE FIRE LOOP 2 STATUS MESSAGE. ITEM M5, FOUND PUSHED PIN ON CONNECTOR D4154B, RESEATED PIN 2. OPERATIONS CHECK IS GOOD AT THIS TIME, IAW WDM 26-11-11 AND AMM OPERATIONS CHECK 26-11-01. REMOVED AND REPLACED FIRE LOOP LOWER FWD, IAW B767 AMM 26-11-02 AS PRECAUTIONARY MEASURE, OPERATIONS CHECK GOOD. P/N OFF 7882, S/N OFF 1979 17NOV20. REMOVED AND REPLACED FIRE LOOP LOWER AFT, IAW B767 AMM 26-11-02 AS PRECAUTIONARY MEASURE. OPERATIONS CHECK GOOD.