What was found
ITEM NR 1 RIGHT ENGINE FUEL CONTROL EICAS MESSAGE ON LANDING. ACCOMPLISHED PIMU BIT, REF B767 FIM 71-01 FAULT TREE 803, NO FAULTS FOUND. PLACED EEC NORM MODE (BOTH ENGINES) ON DEFERRAL, PER MEL 73-21-01-02 DMI 141111, DUE DATE 29JAN21 CAT C, MCC AND DISPATCH NOTIFIED AND PLACARDS INSTALLED. BOTH ENGINES IN ALTN. FOUND "P0 LINE FAIL" ON PIMU, FOLLOWED FIM 71-01 TASK 866. CHECKED PAMB WATER TRAP & FOUND EXCESSIVE WATER DEBRIS, CLEARED TRAP, IAW AMM 73-21-04/601. PIMU BIT GOOD. NO FAULTS. THIS CLEARS MEL, PLACARD REMOVED & MX PROCEDURES C/W.