UPON LANDING WE GOT FWD EQUIPMENT VALVE EICAS MSG, RAN QRH, SELECTED EQUIP COOLING TO STANBY, AFTER 30 SEC LIGHT DID NOT GO OUT. UPON ENGINE SHUTDOWN, LIGHT WENT OUT. PERFORMED FIM TASK 21-58 FT 986, R & R AIR GROUND RELAY, K200 PER SWPM 20-81. PERFORMED OPS CHECK IAW AMM 21-58-00. OPS CHECK GOOD, NO DEFECTS NOTED.