What was found
#2 ENG VIBRATION @ RUN UP REQUIRES REMOVAL CLEAN INSPECTION LUBE REINSTALLATION OF 1ST STAGE BLADES(<P>PERFORMED REMOVED, RELUBE & RE INSTALLATION OF FAN BLADES @ #2 ENG IAW 767 AMM 72-31-02.</P><P>PERFORMED VIB SURVEY IAW 71-00-00 TEST # 6 VIB @ .9 UNITS, FOUND WITHIN LIMITS</P>)