What was found
NO.3 ENG LH C-DUCT FITTING HOLE FOUND ELONGATED REF CMM 78-32-02 REPAIR 020. THE POD SUPPORT FWD BUSHING HOLE MEASURED 1.08" DIA, WHICH HAS EXCEEDES THE MAXIMUM REPAIREABLE LIMIT 0.875" DIA.(<P>THE POD SUPPORT FTG CAN NOT REPLACED AS HAECO DOES NOT HAVE CAPABILITY TO DISASSEMBLE THE UPPER SIDEWALL ASSY FOR THE FITTING REPLACEMENT. THE WHOLE C-DUCT. L3 DUCT REPLACED AS PER AMM 78-31-01.</P>)