What was found
APU GENERATOR NOT SUPPLYING POWER.(<P>REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01, OPS CHECK GOOD. PER FIM 24-20 TASK 805. REMOVED AND REPLACED APU GCU IAW AMM 24-22-02 OPS CHECK GOOD. (GCU P/N OFF 734284F S/N OFF 2232)</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU GENERATOR NOT SUPPLYING POWER.(<P>REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01, OPS CHECK GOOD. PER FIM 24-20 TASK 805. REMOVED AND REPLACED APU GCU IAW AMM 24-22-02 OPS CHECK GOOD. (GCU P/N OFF 734284F S/N OFF 2232)</P>)