As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO COMPARTMENT FLOOR SHEAR WEB HAS AREA OF CORROSION AT BONDING JUMPER ATTACH AREA BS 1330 RBL 40. DOT 016(<P>UPON EVAL. OF FLOOR SHEAR WEB STA. 1330 RBL 40. FOUND 100% OUT OF LIMITS IAW B767 SRM 51-70-13-0G-0. REMOVED AND REPLACED SHEAR WB IAW B767 SRM 53-60-53-01-1 LOCATED IN AFT PIT<BR /></P>)