Service difficulty report · Valve · Boeing 767306

Difficulty date
July 3, 2021
Submitted
July 7, 2021
Operation
Air carrier
Aircraft
N1427A
Make and model
Boeing 767306
Aircraft serial
28098
Aircraft time
83,986 hours
Part
Valve
Part number
2780540101
Part serial
1901
Condition
Failed
Location
Apu Pneumatic
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU PNEUMATICS INOP(<P>TRANSFERRED TO MDDR 149618 IAW MEL 49-11-01-01, CAT C.</P> / <P>LP 1361901 - ON A/C ARRIVAL WE ACTIVATED PNEUMATICS ON APU, WE HAD 30 PSI OF DUCT PRESSURE WITH PACKS OFF, WITH BOTH PACKS RUNNING WE HAVE 20-25 PSI OF DUCT PRESSURE, RAN APU PNEUMATICS WITH HIGH DEMAND FOR APPROX 4HRS AND NEVER LOST PNEUMATICS. WE COULD NOT DUPLICATE FAULT ON GROUND, SUSPECT FAULT ONLY OCCURS AT LANDING WHEN MOISTURE IS PRESENT ON APU LINES AND VLV. DMI REMAINS OPEN FOR CONTINUED T/S.</P> / <P>LP 1363575 - REMOVED AND REPLACED APU BLEED SHUTOFF VLV IAW 36-11-00. OPS CKS NORMAL AT THIS TIME. THIS CLEARS MDDR 149618.</P>)