What was found
STAUS MSG R ENG HPSOV STARTED ON APPROACH AS AN INTERMITTENT EICAS MESSAGE.(<P>PERFORMED AIR SUPPLY CTRL BITE TEST PER AMM 36-23-00. FOUND R HPSOV WIRE FAULT. PERF FIM 36-10 FT 833. DURING WIRE CHECKS FOUND CONNECTOR D4E10P LOOSE. RE-TIGHTENED CONNECTOR D4210P PER SWPM 20-60-06. OPS CKS GOOD. MESSAGE CLEARED . SEE LP #1461412 ITEM 4, PERFORMED ENGINE RUN IAW 71-00-00, NO DEFECTS NOTED @ THIS TIME.</P>)