What was found
AFTER BLOCK IN EICAS MSG "APU FAULT". PERFORMED APU OPS TEST IAW B767 AMM 49-11-00/201. OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER BLOCK IN EICAS MSG "APU FAULT". PERFORMED APU OPS TEST IAW B767 AMM 49-11-00/201. OPS NORMAL.