Service difficulty report · Actuator · Boeing 7673S1

Difficulty date
September 1, 2021
Submitted
September 14, 2021
Operation
Air carrier
Aircraft
N640GT
Make and model
Boeing 7673S1
Aircraft serial
25221
Aircraft time
93,918 hours
Part
Actuator
Condition
Failed
Location
Lt Ram Air
Stage of operation
NR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT PACK AUTO FUNCTION INOP ( PACK TEMPERATURE CONTROL SYSTEMS (-200/-300) , AUTO MODE), PLACARD INSTALLED. 1484465/21/BWI- REMOVED AND REPLACED LEFT PACK LOW LIMIT VALVE (V131) IAW AMM 21-51-11. OPERATIONAL CHECK GOOD, AUTO AND MANUAL MODES FUNCTION NORMALLY.LOG PAGE 1484468: LH PACK TEMP EICAS MESSAGE UPON PUSHBACK, RETURN TO GATE. PERFORMED PACK TEMP CONTROLLER BITE IAW FIM 21-51-001/101 FIG 103, RAM INLET ACT FAULT. RAM INLET ACTUATOR R & R PCW PER TABLE A. PERFORMED LEFT PACK TEMP CONTROLLER RESISTANCE CHECK, FROM CONTROLLER D 958B PIN B13 TO CONNECTOR D 958C PIN4, PINB15 TO PIN 4. BOTH CHECK GOOD. PERFORMED TABLE B SHEET 3 PACK TEMP CONTROLLER FAULT LIGHT T SHOOTING, BLOCK 1 THROUGH 2. PLW BLOCK 3. PERFORMED CHECK OF WIRING FOR LIMIT SWITCHES. ALL CHECKED GOOD. BLOCK 4 CHECK WIRING FOR POTENTIOMETER, CHECK GOOD. ITEM 5: CHECKED WIRING FOR VALVE DRIVER CIRCUIT, CHECK GOOD. SWAPPED LH & RH RAM INLET ACTUATORS IAW AMM 21-53-03-004/404, FAULT FOLLOWED, RETURNED RAM INLET ACTUATORS TO ORIGINAL POSITIONS. R & R LT RAM INLET ACTUATOR. SYS OPS TEST GOOD IAW AMM 21-53-004/404. PERFORMED GROUND ENG RUN-UP PER GROUND RUN-UP PROCEDURES AMM 72-00-00. ALL SYS OPS NORMAL.

More about the Boeing 767-3S1