What was found
RT ENG FIRE LOOP 1 STATUS MESSAGE ( ENGINE FIRE DETECTION SYSTEMS, DETECTION LOOPS (ER RESTRICTED 120 MIN) )(<P>TRANSFERRED TO MEL 26-11-01-01, MDDR 153007, CAT C, DUE ON 14 SEP21 </P> / <P>LP 1484434 ITEM 6: RESEATED M10274 LOGIC TEST FIRE /OVHT CARD IN P54 AND MESSAGE CLEARED. PER SSM 26-11-02 AND PERFORMED ENGINE FIRE/OVERHEAT TEST PER 26-11-01. OPS CHECK GOOD. THIS CLEARS MDDR 153007.</P>)