What was found
LT PACK TEMP EICAS MESSAGE.(<P><SPAN>DEFERRED IAW MEL 21-51-01-01. TRANSFERRED TO MDDR 153391.</SPAN></P> / <P>LP 1386797: REMOVED AND REPLACED TEMP CONTROL VALVE IAW AMM 21-51-12. OPS CHECK GOOD. UPON INSPECTION FOUND RAM INLET DOOR CLOSED LH SIDE AND FOUND ACTUATOR ON RAM INLET DOOR NOT WORKING PROPERLY TO KEEP THE DOOR FULLY OPEN.</P> / <P>LP 1386798: REMOVED AND REPLACED RAM AIR INLET DOOR ACTUATOR IAW AMM 21-53-03. OPS CHECK GOOD. THIS CLEARS DMI 153391. PLAC REMOVED.</P>)