What was found
R ENG HPSOV INOP ( (HPSOV) (SECURED CLOSED) )(<P>DEFERRED INOP AS PER MEL 36-11-02-02, CAT C, MDDR 154961, ASSIGNED ACTIONS C/W.</P> / <P>17OCT-BWI MX: LP 1474431, ITEM M6: R&R CONTROL ASSY. FOR RH HPSOV IAW AMM 36-11-08. OPS CHECK GOOD. NO LEAKS & NO FAULTS ON BITE TEST. </P> / <P>LP 1474432, ITEM M7: PER AMM 36-11-08 ENGINE RUN NOT REQUIRED. REFERENCE LP 1474431 ITEM M6 FOR R/R OF HPSOV CONTROLLER AND OPS CHECK. THIS