What was found
PITTING CORROSION - SKIN, NO. 1 PYLON AFT STRUT FAIRING FWD BULKHEAD(<P>BLENDED OUT THE DAMAGED AREA IAW SRM 51-10-02 REV. 50. PERFORM NDT INSPECTION, REFER TO JOB CARD ATTACHING SHEET NO. 0305381. MEASURED REWORK AREA DEPTH = 0.001" LENGTH = 1", WIDTH = 0.8" IT WAS ALLOWABLE IAW SRM 54-50-02-1A-1 FIG 101 DETAIL IV REV. 50. APPLY PROTECTIVE COATING AT REWORK AREA IAW SRM 51-20-01 REV 50. JOB COMPLETED AND CONDITION CHECK NORMAL.</P>)