What was found
DENT - RH WING INBD #8 SPOILER UPPER SKIN(<P>CUT OUT THE DAMAGE MATERIAL AND CLEAN.MEASURE THE DAMAGE SIZE L=2.6", W=1.5", 2/3" FROM INBD EDGE, 2" FROM AFT EDGE. BOND REPAIR FILLER AND DOUBLER WITH FILM ADHESIVE. CURE AT 250 DEGREES F FOR 120 MINS. MAINTAIN MINIMUM VACUUM PRESSURE. IAW SRM 57-70-02-2R-1. COND CHK NML.</P>)