FOUND FLOOR BEAM CAP CORROSION AT STATION 2360, RBL 11.33, LBL 39(<P>1) REMOVED DAMAGE PART IAW SRM 51-40-02 REV 94. 2) FABRICATED PART IAW EI # T2022 P53M-1034 REV 0. 3) INSTALLED FABRICATE PART IAW SRM 51-40-02 REV 94 AND BNG NO 65B02634 SH22 REV, U SH 60 REV, 65B06161 SH02 REV E, 65B38754 SH08 REV A, 65B06154 SH01 REV H, 65B06156 SH02 REV E AND 65B38694 SH07 REV- 4.JOB COMPLETED AND CONDITION CHECK NORMAL</P>)