What was found
CORROSION DAMAGE ON LH HST CENTER SECTION UPPER SKIN TOP SURFACE BETWEEN STAB STA 165.64 AND 172.4, STRINGER 3(<P>1) REMOVER THE AFFECTED FASTENERS IAW SRM 51-40-02 REV 94. 2) BLENDED OUT THE DAMAGE AREA IAW SRM 51-10-02 REV 94. 3) PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET NO 0325737 AND DATA SHEET NO 6918368-1. 4) ACCOMPLISHED EI NO T2022A55M-1031 REV 2. 5) CONDITION CHECK NORMAL AND JOB COMPLETED</P>)